PLEASE NOTE THAT VOR ORDERS CAN BE PLACED BY TELEPHONE UP UNTIL 5.30PM MONDAY-THURSDAY & UP UNTIL 5PM ON FRIDAYS
Please be advised that part no. K159939B90 is now made from the new part no. K192161N00. This unit is fully crimped and cannot be spun (Up2date Y498007).
Please be advised that part no. K159939B90 is now made from the new part no. K192161N00. This unit is fully crimped and cannot be spun (Up2date Y498007).
Please enter at least 3 characters

Air Processing Unit
ID:
K060707
- ZE4501
- Air Processing Unit
- Non saleable to the IAM
Compare
999999 In Stock
Added to Cart

IAM part number/s for K060707
K060707N00
ZE4501
Air Processing Unit
Saleable to the IAM
Weights & Dimensions
Gross Weight
5.9 Kilogram
Net Weight
5.9 Kilogram
Length
317.0 Millimeter
Width
207.0 Millimeter
Height
314.0 Millimeter
Customs Information
Country of Origin*
Hungary
Customs Tariff Number*
84213925
*
Subject to change based on delivering warehouses; for further details contact your local customer service.
Air Inlet port(s) size
M22x1,5
Air Delivery port(s) size
21, 22, 23, 24:M16x1,5: 26: M22x1,5
Purge control
Electrical
Tyre Inflator port size
M22x1,5
Unloader cut-out pressure [bar]
11,2
Unloader pressure control range [bar]
programmable
Circuit 1
Feedback with Bypass
Circuit 1 - Open/close pressure [bar]
7.5 + 0.3 / 6.5 ± 0.25
Circuit 1 - Pressure Limiting [bar]
Not included
Circuit 2
Feedback with Bypass
Circuit 2 - Open/close pressure [bar]
7.5 + 0.3 / 6.5 ± 0.25
Circuit 2 - Pressure Limiting [bar]
Not included
Circuit 3
Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]
7.5 +0.1 -0.2 / 5.9 ± 0.2
Circuit 3 - Pressure Limiting [bar]
8,5 +0,0/-0,3
Circuit 4
Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]
7.5 +0.1 -0.2 / 5.9 ± 0.2
Circuit 4 - Pressure Limiting [bar]
8,5 +0,0/-0,3
Bleed-back safety feature
Controlled by Circuit 1
Circuits' supply
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing
Yes
Exhaust Connector
Ø 16,0 mm Push Connector
Heater Connection Type
Bayonet ISO 15170 A1 - 2.1.1.Ag/K3
Heater Voltage [volts]
24 V
Air dryer part number
K011867
Four circuit protection valve part number
K048307
Cartridge type
Conventional
Semi Electonic Control
Yes