With immediate effect please select the 'replaced by' part number when entering an order for the following part numbers:
K019309B90 replaced by K019309V06N50, K019319B90 replaced by K019319V06N50, K055369B90 replaced by K055369V05N50, K055379B90 replaced by K055379V05N50, K110619B90 replaced by K110619V04N50
K019309B90 replaced by K019309V06N50, K019319B90 replaced by K019319V06N50, K055369B90 replaced by K055369V05N50, K055379B90 replaced by K055379V05N50, K110619B90 replaced by K110619V04N50
Please enter at least 3 characters

Air Processing Unit
ID:
K012243N00
999999 In Stock
Added to Cart

IAM part number/s for K012243N00
K012243N00
ZB4587
Air Processing Unit
Saleable to the IAM - whilst stocks last
Weights & Dimensions
Gross Weight
7.87 Kilogram
Net Weight
6.84 Kilogram
Customs Information
Country of Origin*
Hungary
Customs Tariff Number*
84213925
*
Subject to change based on delivering warehouses; for further details contact your local customer service.
Air Inlet port(s) size
M22x1,5
Air Delivery port(s) size
21, 22, 23, 24:M16x1,5: 25, 26:M22x1,5
Tyre Inflator port size
M22x1,5
Unloader cut-out pressure [bar]
10,5
Unloader pressure control range [bar]
0,8
Circuit 1
Feedback with Bypass
Circuit 1 - Open/close pressure [bar]
7,5/6,5
Circuit 1 - Pressure Limiting [bar]
Not included
Circuit 2
Feedback with Bypass
Circuit 2 - Open/close pressure [bar]
7,5/6,5
Circuit 2 - Pressure Limiting [bar]
Not included
Circuit 3
Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]
7,5/5,9
Circuit 3 - Pressure Limiting [bar]
8,5
Circuit 4
Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]
7,5/5,9
Circuit 4 - Pressure Limiting [bar]
8,5
Bleed-back safety feature
Controlled by Circuit 1
Circuits' supply
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing
No
Heater Connection Type
Bayonet ISO 15170 A1 - 2.1.1.Ag/K3
Heater Voltage [volts]
24 V
Replacement Products