Skip to content Skip to navigation menu
You cannot place an order at this time, pleaseContact Us for further assistance
Spinner
K051290
  • AE4546
  • Four Circuit Prot. Valve
  • Non saleable to the IAM
Compare

available online

Spinner
Recommended IAM part numbers for K051290 including Service New + EconX:

Weights & Dimensions

Gross Weight
1.8 Kilogram
Net Weight
1.8 Kilogram
Length
191.0 Millimeter
Width
102.0 Millimeter
Height
151.8 Millimeter
Air Inlet port(s) size
M16x1,5 
Air Delivery port(s) size
21,22,23,24,25,26: Voss NG12 M22x1,5 
Circuit 1
Feedback with Bypass 
Circuit 1 - Open/close pressure [bar]
7,0-0,3 / >=4,5 
Circuit 1 - Pressure Limiting [bar]
10,4 +0,0/-0,4 
Circuit 2
Feedback with Bypass 
Circuit 2 - Open/close pressure [bar]
7,0-0,3 / >=4,5 
Circuit 2 - Pressure Limiting [bar]
10,4 +0,0/-0,4 
Circuit 3
Non-feedback with no Bypass 
Circuit 3 - Open/close pressure [bar]
7,5-0,3 / >=4,5 
Circuit 3 - Pressure Limiting [bar]
8,5 +0,0/-0,4 
Circuit 4
Feedback with Bypass 
Circuit 4 - Open/close pressure [bar]
7,0-0,3 / >=4,5 
Circuit 4 - Pressure Limiting [bar]
Not included 
Bleed-back safety feature
Controlled by Circuit 1 
Circuits' supply
Internal series supply from 4 and 1 and 2 to 3 
With Electrical pressure sensing
Yes 
IAM Part No.
Four Circuit Prot. Valve
AE4546
Four Circuit Prot. Valve
Saleable to the IAM
AE4546
Four Circuit Prot. Valve
Saleable to the IAM
Spares/Service Kits
Four Circuit Prot. Valve
AE4546
Four Circuit Prot. Valve
Saleable to the IAM
AE4546
Four Circuit Prot. Valve
Saleable to the IAM
Pressure Sensor
Pressure Sensor
Saleable to the IAM
Pressure Sensor
Saleable to the IAM